|
|
Instruments for surgery and prosthesis
|
|
• Material: titanium alloy • Facilitates measurement of the depth after use of drill ø2
• The apical sphere allows for tactile examination of the osteotomy |
|
|
Height (h) |
Code |
Code |
Code |
|
| 14 |
DEX235 |
DEX235 |
DEX235 |
| |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
• Material:
surgical steel • 14mm-long extension for all types of drills and screwdrivers |
|
|
Height (h) |
Code |
Code |
Code |
|
| 5,3 |
CMC037 |
CMC037 |
CMC037 |
| 11,3 |
CML037 |
CML037 |
CML037 |
| |
|
|
|
|
|
|
• Material:
surgical steel • Makes it possible to screw-in the implants and to tap with the handpiece |
|
|
Height (h) |
Code |
Code |
Code |
|
| 3,5 |
RDC3727 |
RDC4527 |
RDC5527 |
| 8,5 |
RDC3732 |
RDC4532 |
RDC4532 |
| |
|
|
|
|
| |
|
|
|
|
|
|
• Material:
surgical steel • Colour code • Makes it possible to screw-in the implants with the handpiece after removing the mounth |
|
|
Height (h) |
Code |
Code |
Code |
|
| 5,6 |
001145 |
001147 |
ILC5519 |
| 11,6 |
001146 |
001148 |
ILC5525 |
| |
|
|
|
|
|
|
• Material:
surgical steel • Colour code • Makes it possible to screw-in the plants manually after having removed the mounth |
|
|
Height (h) |
Code |
Code |
Code |
|
| 11 |
001162 |
001162 |
001162 |
| |
|
|
|
|
|
|
• Material:
surgical steel • Used for the manual positioning of the implants and manual tapping |
|
|
Height (h) |
Code |
Code |
Code |
|
| 11 |
110026 |
110026 |
110026 |
| |
|
|
|
|
|
|
• Material:
surgical steel • Extends the length of connection between mounth, insert, tapper, wrench and ratchet |
|
|
Height (h) |
Code |
Code |
Code |
|
| 7,5 |
001151 |
001151 |
001151 |
| 13,5 |
001152 |
001152 |
001152 |
| |
|
|
|
|
|
|
• Material:
surgical steel • Used for the cover screws, all gingival conditioners, fixing screws for the abutment and the screws of the mounth |
|
|
• Material:
surgical steel • Used to limit the effects of screwing and unscrewing the mounth screws. |
|
|
• Material:
surgical steel • For handling titanium implants and components. |
|
|
• Material:
surgical steel • Used in the fixed way for the manual positioning of the implants and manual tapping • In a dynamometric position, allows the staff to operate at specific Newton levels |
|
|
Height (h) |
Code |
Code |
Code |
|
| 7 |
TW0001C |
TW0001C |
TW0001C |
| 13 |
TW0001L |
TW0001L |
TW0001L |
| |
|
|
|
|
|
|
• Material:
surgical steel • To screw-in the fixing screws of the abutment connected to the dynamometric wrench code CRDN001 |
Driver adapter one piece abutment
|
|
|
Height (h) |
Code |
Code |
Code |
|
| 13 |
TW0015C |
TW0015C |
|
| 19 |
TW0015L |
TW0015L |
|
| |
|
|
|
|
|
|
• Material:
surgical steel • To screw-in the abutment connected to the dynamometric wrench code CRDN001 |
Octagonal adapter for abutment E.M.
|
|
|
• Material:
surgical steel •
To screw-in the E.M. abutment connected to the dynamometric wrench code CRDN001 • Dedicated instruments, codes 001151 – 52 |
|
|
Height (h) |
Code |
Code |
Code |
|
| 14 |
DRP200 |
DRP200 |
DRP200 |
| |
DRP325 |
DRP425 |
DRP500 |
| |
|
|
|
|
|
|
• Material:
surgical steel • To screw-in the ball attachment with the dynamometric wrench code CRDN001 end/or hand piece |
|